Areva Relay
Sr. No | DESCRIPTION | Relay Type |
---|---|---|
1 | Battery E/F relay Self Powered Battery voltage 24, 48, 110, 220V DC Setting 1 to 7mA, Aux Contacts 2NO SR & 3NC+1NO SR Flag | CAEM21 (2NO SR) |
2 | Second Rotar E/F relay | CAEM33 |
3 | AC Instantaneous O/C Relay | CAG11 |
4 | AC Instantaneous O/C or E/F relay 2 N/O S/R | CAG12 |
5 | AC Instantaneous O/C or E/F relay 1NO+1NC S/R contacts O/C 50- 200% & E/F 20-80% or 10-40% of 5A or 1A | CAG12C |
6 | 1ph AC Instantaneous circulating current relay with tuned circuits & adjustable setting 10-40% or 20- 80% of 5A or 1A with external Stabilizing resistor & 2NO SR contacts. | CAG14 |
7 | 3ph AC Instantaneous circulating current relay with tuned circuits & adjustable setting 10-40% or 20- 80% of 5A or 1A with external Stabilizing resistor & 2NO SR contacts. | CAG34 |
8 | 1 Pole High Impedance Differential relay | FAC14 |
9 | 3 Pole High Impedance Differential relay | FAC34 |
10 | 1 Pole AC Instantaneous O/C relay 5A or 1A; 250-2000% or 200-800% 2 NO S/R. | CAG14 |
11 | 3 Pole AC Instantaneous O/C relay 5A or 1A; 250-2000% or 200-800% 2 NO S/R. | CAG34 |
12 | Sensitive instantaneous voltage polarised directional relay with integral timer relay (reverse power aux) 2NO SR Contacts & aux. supply 30/110/220V DC CTR 5A or 1A PT volts 110V AC MTA 30 & timing .5-5 or 1-10, 2.5-25 sec | CCUM21 |
13 | Directional IDMT voltage current polarized O/C or E/F relay 2NO SR / 2NO HR setting O/C 50-200% or 10-40% of 5 or 1A CTR. Single Pole | CDD21 |
14 | 1 Pole Non-Directional 3VA IDMT O/C or E/F or O/C & E/F relay 2NO S/R / 2NO+2NC HR contact setting O/C 50-200% & E/F 20-80% or 10-40% of 5A or 1A Self powered. DMT 3 / 1.3 Sec | CDG11 |
15 | 3 Pole Non-Directional 3VA IDMT O/C or E/F or O/C & E/F relay 2NO S/R / 2NO+2NC HR contact setting O/C 50-200% & E/F 20-80% or 10-40% of 5A or 1A Self powered. DMT 3 / 1.3 Sec | CDG31 |
16 | Non-directional IDMT O/C or E/F relay O/C 50-200%, E/F 20-80% or 10-40% fitted with highest relay type CAG17 O/C 200-2000% E/F 100-800% CTR 5A or 1A 2NO S/R or 2NO + 2NC HR self powered. | CDG21 |
17 | IDMT relay with 2 O/C CDG11 & 1 E/F CAG14 2NO SR self powered | CDAG31 |
18 | Non-directional IDMT relay 2 O/C 50-200% with highset setting 250 – 2000% type CAG17 & E/F relay setting 10-40% or 20-80% type CAG14 CTR 5A or 1A self powered 2NO S/R contacts | CDAG51 |
19 | Non-directional IDMT 3 O/C relay with U/V control 2NO S/R contact adjustable setting 50-200% of 5A or 1A 2NO S/R. –do– 2NO H/R | CDV62 |
20 | 1 Pole Inverse time (long time delay) stand by earth fault relay 15-20% 5A or 1A 2NO S/R / H/R Aux. DC. | CDG12 |
21 | 1 Pole IDMT relay O/C or E/F 5A or 1A 1.5 Sec. 2 NO S/R / H/R & DC aux | CDG13 |
22 | 3 Pole IDMT relay O/C or E/F 5A or 1A 1.5 Sec. 2 NO S/R / H/R & DC aux | CDG33 |
23 | 1 Pole IDMT extremely inverse time O/C or E/F 5A or 1A | CDG14 |
24 | 3 Pole IDMT extremely inverse time O/C or E/F 5A or 1A | CDG34 |
25 | IDMT extremely inverse time O/C or E/F 5A or 1A | CDG24 |
26 | 3 Pole IDMT extremely inverse time O/C or E/F 5A or 1A | CDGM12 |
27 | Definite time negative phase seq. current relay for single phasing & unbalance detection. CTR 5A or 1A volt 110/250V AC/DC setting 10% or 20% time 3/6/9 sec. | CTNM12 |
28 | 1 Pole Static definite time O/C or E/F relay | CTU12 |
29 | 3 Pole Static definite time O/C or E/F relay | CTU32 |
30 | 1 Pole Sensitive definite time Static E/F relay | CTU15 |
31 | 1 Pole Sensitive definite time Static E/F relay | CTUM15 |
32 | Static Motor Protection relays for Motors controlled by Circuit Brks. -do- but controlled by Contactors | CTMM501-510 |
33 | Static Motor Protection relays for Motors controlled by Circuit Brks. -do- but controlled by Contactors | CTMFM401-410 |
34 | Static Negative phase seq. Relay Extra for one heavy current test plug and extention cord for above | CTNM31 |
35 | Breaker Backup relay 3-Pole | MCTIG40-L |
36 | Static single pole instaneneous sensitive E/F relay. | CTIGM15 |
37 | High speed differential relay for two winding transformer CTR 5A or 1A diff. setting 15% Bias setting 15-30-45% Aux voltage 24/30/110 /220V DC 2NO S/R. | DTH31 |
38 | High speed differential relay for two winding transformer CTR 5A or 1A diff. setting 15% Bias setting 15-30-45% Aux voltage 24/30/110 /220V DC 2NO S/R. | DTH32 |
39 | Test Plug Universal Test Block | MPB |
40 | Test Plug Universal Test Block | MPG |
41 | Digital Over/Under frequency protective relay. Single Stage | MFVUM12 |
42 | Digital Over/Under frequency protective relay. Two Stage | MFVUM22 |
43 | 1-Phase Transformer diff. Relay. 2 winding Transformer | MBCH12 |
44 | 1-Phase Transformer diff. Relay. 3 winding Transformer | MBCH13 |
45 | Aux relay 2M & 2C/O S/R contact | MVAAM11 |
46 | Aux relay 2M & 2C/O S/R contact with 2 elements & 4 C/O | MVAAM21 |
47 | Aux relay 2M & 2C/O S/R contact with 3 elements & 4 C/O | MVAAM31 |
48 | Aux relay 2M & 2C/O S/R contact with 4 elements & 8 C/O | MVAAM41 |
49 | Aux relay 2M & 2C/O S/R contact with 5 elements & 8 C/O | MVAAM51 |
50 | Aux relay 2M & 2C/O S/R contact with 6 elements & 8 C/O | MVAAM61 |
51 | Aux relay 2M & 2C HR Contacts | MVAAM13 |
52 | Aux relay 4M & 4C HR Contacts | MVAAM23 |
53 | Single pole high stability circulatng current relay | MCAG14 |
54 | 3 pole high stability circulatng current relay | MCAG34 |
55 | Trip Circuit Supervision relay with prclosing & post-closing supervision having S/R contacts & rev. flag | MVAXM21 |
56 | Trip Circuit Supervision relay with prclosing & post-closing supervision having S/R contacts & rev. flag | MVAXM31 |
57 | 1 element voltage operated tripping relay with S/R contacts | MVAJM11 |
58 | 1 element voltage operated tripping relay with S/R contacts | MVAJM13 |
59 | 1 element voltage operated tripping relay with High Burden | MVAJM15 |
60 | 1 element voltage operated tripping relay with 2 elements | MVAJM25 |
61 | 1 Element voltage operated control relay with electrical reset contacts | MVAJM14 |
62 | 4 element tripping relay with S/R contacts but w/o flag. | MVAJM41 |
63 | 4 element tripping relay with S/R contacts but with flag | MVAJM45 |
64 | Voltage selection relay with S/R contacts & H/R flag | MVAPM32 |
65 | Static Inv. time 1-Ph O/C or E/F relay with std. Inv. Time charc | MCTGM11 |
66 | Static Inv. time 1-Ph O/C or E/F relay with inst. Highset unit | MCTGM21 |
67 | Static digital time delay relay with delay on Pick-up | MVTTM14 |
68 | Static digital time delay relay with delay on Drop-off | MVTTM15 |
69 | Spring return T-N-C Switch S04N120SRPM101 | ODS |
70 | Spring return T-N-C Switch S06N120SRSPM116 | ODS |
71 | Spring return T-N-C Switch S06N120SRL2PM111 | ODS |
72 | Check Synchronising relay for Generator Protection 110V AC phase angle 10 deg. Time setting 0.5/3 secs 1NO+1NC or 2NO SR Aux. 48/110V/220V DC. | SKE11 |
73 | Check Synchronising relay for Generator Protection 110V AC phase angle 10 deg. Time setting 0.5/3 secs 1NO+1NC or 2NO SR Power Pack of 110V AC for above | SKD11 |
74 | Instantaneous N/V relay with reverse or no flag 1M 1B S/R contacts voltage rating 30/110V DC or 110/220V AC Instantaneous AC fixed setting U/V or O/V & DC O/V relay with or without flag with 1M 1B S/R 1B S/R contacts | VAG11 |
75 | Instantaneous AC / DC with fixed setting U/V or O/V relay with or without flag & with an additional AC or DC aux. Unit having 2NO+1NC SR contacts. Std range Extra for high drop off or pick up ratio of U/V relays having setting other than 30 to 60% | VAG21 |
76 | 3 element Inst. U/V relay | VAG31 |
77 | O/V relay 110V AC with adjustable setting 110-140% with flag self powered 2NO+1NC SR cont. Extra for ext. PT 440/250/110VAC | VAGM22 |
78 | U/V relay with setting 40- 80% of 110V AC 1NO+2NC SR Extra for ext. PT 440/250/110VAC | VAGM22 |
79 | Inverse time O/V relay setting range 110-170% of 110V AC 1NO+ 1 C/O S/R self powered. | VDG11 |
80 | Inverse time U/V relay 2M S/R contacts on a shunt reinforcing unit set range 50-90% 110VAC Aux 24- 250V DC. Extra for Ext. PT 250/440V AC | VDG13 |
81 | Neutral displacement relay 2NO S/R contacts on a shunt reinforcing unit voltage setting 5.4-20V Aux.24-250 V DC. | VDG14 |
82 | Fuse failure relay 110V AC 50Hz 1NO 1 NC S/R contacts with flag Special Resistors | VAPM31 |
83 | Voltage operated Auxilliary relays with/without flag. 2NO + 2 C/O S/R contacts (DC) extra for AC Voltage | VAA11 |
84 | Voltage operated Auxilliary relays with/without flag. 2NO + 1 C/O S/R contacts (DC) extra for AC Voltage | VAA21 |
85 | Voltage operated Auxilliary relays with/without flag. 1NO+1NC S/R cont. or 2NO SR | VAA31 |
86 | Voltage operated Auxilliary relays with/without flag. 4 element relay with flag | VAA41 |
87 | Voltage operated Auxilliary relays with/without flag. Spl. Aux. Relay for Vg selection | VAA51 |
88 | Voltage operated Auxilliary relays with/without flag. 2NO + 2 C/O H/R contacts (DC) extra for AC Voltage | VAA13 |
89 | Voltage operated Auxilliary relays with/without flag. 2NO + 1 C/O H/R contacts (DC) extra for AC Voltage | VAA23 |
90 | Voltage operated Auxilliary relays with/without flag. 1NO + 1NC or 2NO H/R contacts | VAA33 |
91 | Voltage operated Auxilliary relays with/without flag. Plug in type relays 6 pair of contacts, DC operation. | VAA11 |
92 | Sp. Aux. Relay for use with 3 initiating contacts in our Std Electromechanical Scheme | VAA61 |
93 | Sp. Aux. Relay for use with 3 initiating contacts in our Std with 4 contacts | VAA81 |
94 | Sp. Aux. Relay for use with 3 initiating contacts in our Std with 6 contacts | VAA121 |
95 | 1 Pole High Speed Tripping relay with 4pairs of H/R contacts. | VAJH13 |
96 | 2 Pole High Speed Tripping relay with 4pairs of H/R contacts. | VAJH23 |
97 | High Speed Tripping relay with 4pairs of H/R contacts with trip circuit supervision | VAJHM13 |
98 | High Speed Tripping relay with 4pairs of H/R contacts with 2 Element | VAJHM23 |
99 | High Speed Tripping relay with 4pairs of H/R contacts with 3 Element | VAJHM33 |
100 | High Speed Tripping relay with 4pairs of H/R contacts with 5 Element | VAJHM53 |
101 | Control relay with 8 electrically reset pairs of contacts & DC Aux | VAJC11 |
102 | Semaphore Indicators DC 30/110V/220V/AC110/230V AC | VAM12 |
103 | Semaphore Indicators DC 30/110V/220V/AC110/230V AC | VAM22 |
104 | Trip Circuit supervision relay 2NC + 1NO S/R contacts 30/110V/230V DC | VAX21 |
105 | Trip Circuit supervision relay 2NC + 1NO S/R contacts 30/110V/230V DC | VAX31 |
106 | Static Definite time delay relay 4 pairs of S/R cont. upto 12-120 sec Aux. Voltage DC extra for 30-300 secs extra for addl. pair of contacts for VTT12/14/15 | VTT11/VTT12 |
107 | Static Definite time delay relay 4 pairs of S/R cont. upto 12-120 sec Aux. Voltage AC extra for 30-300 secs extra for addl. pair of contacts for VTT12/14/15 | VTT11/VTT12 |
108 | Static Definite time delay relay 4 pairs of S/R cont. upto 12-120 sec Aux. Voltage DC extra for 30-300 secs extra for addl. pair of contacts for VTT12/14/15 | VTT14/VTT15 |
109 | Static Definite time delay relay 4 pairs of S/R cont. upto 12-120 sec Aux. Voltage AC extra for 30-300 secs extra for addl. pair of contacts for VTT12/14/15 | VTT14/VTT15 |
110 | Sensitive Low Reverse power relay | WCDM11 |
111 | Sensitive Low Forward power relay | WCDM13 |
112 | Aux. relays combined S/R & HR contacts | VAA12 |
113 | Aux. relays combined S/R & HR contacts | VAA22 |
114 | Aux. relays combined S/R & HR contacts | VAA32 |
115 | Static negative phase sequence voltage relay | VTNM12 |
116 | Static instantaneous U/V relay | VTIGM12 |
117 | Static definite time O/V relay | VTU21 |
118 | Static definite time U/V relay but 3 Phase | VTUM21 |
119 | Static definite time U/V relay but 3 Phase | VTUM61 |
120 | Static combined definite time & instantaneous overvoltage relay | VTU31 |
121 | Voltage balance relay for use in generator protection | VAGM61 |
122 | Negative potential biased earth leakage relay. | VAEM22 |
123 | Rotor Earth fault relay | VAEM21 |
124 | Under voltage relay | VAGM23 |
125 | 1 Pole High speed Tripping relay with S/R contacts. | VAJS13 |
126 | 2 Pole High speed Tripping relay with S/R contacts. | VAJS23 |
127 | Interposing Relay | VAWA12 |
128 | Interposing Relay | VAWA22 |
129 | Field Failure Relay | YCGF11 |
130 | Busbar protection pilot supervison relay S/R contacts extra for 4 pairs H/R contacts | VTX31 |
131 | Definite Time Over Fluxing relay | GTT21 |
132 | Definite Time Over Fluxing relay | GTTM22 |
133 | Feeder Protection Relay Set Using Pvt. Pilots with facility to supervise the healthness of pilots comprising of Relays for (a) Sending End (b) Receiving End (c) Injection Unit (d) Measuring & Pilot supervision unit | HORM4 |
134 | Static Industrial Timer | TimEE |
135 | Sensitive Earth Leakage relay to be used with CBCT (extra cost) | EarthLEE |
136 | Voltage Operated Single Phasing unbalance preventor for motors | SuperEEmo |